-
AINSEBLUE
For easy transfer of washed sperm into the uterine cavity, in Artificial Insemination procedures. Single lumen, radiopaque transparent catheter with different stiffness: – Rigid proximal portion (2) for easy insertion through the […]
-
AINSEBLUE-T
For easy transfer of washed sperm into the uterine cavity, in Artificial Insemination procedures. Single lumen, radiopaque transparent catheter with different stiffness: – Rigid proximal portion (2) for easy insertion through the […]
-
AINSEGREY
For easy transfer of washed sperm into the uterine cavity, in Artificial Insemination procedures. Centimeter-marked catheters (3) with rounded tip (4) and double side-eyes. Material transparency allows visual proof of successful transfer. A luer […]
-
AINSEWHITE
For easy transfer of washed sperm into the uterine cavity, in Artificial Insemination procedures. Centimeter-marked catheters (3) with rounded tip (4) and double side-eyes. Material transparency allows visual proof of successful transfer. A luer lock […]
-
ALCO-RAM
Disposable needle for hepatic alcoholization. A distal side-holes cannula is designed to perform an homugeneous intra-arterial alcoholization. The needle is provided with an universal luer lock cone and a 15 […]
-
BIMONOCYTE
For atraumatic oocyte aspiration in IVF procedures. Single lumen, double-way needle, one way for oocyte aspiration (5), second way for follicle flushing (3). Echogenic tip with atraumatic bevel (1).Oocyte aspiration is performed […]
-
BIMONOCYTE-N
For atraumatic oocyte aspiration in IVF procedures. Single lumen, double-way needle, one way for oocyte aspiration (5), second way for follicle flushing (3). Echogenic tip with atraumatic bevel (1).Oocyte aspiration is performed […]
-
CHIBA
Chiba tip disposable needle used for cytological aspiration and local anaesthesia administration. The needle cannula is centimeter marked in order to make the procedure as precise as possible. An echogenic […]
-
DOUBLECYTE
For atraumatic oocyte aspiration in IVF procedures. Double lumen, double-way needle, one way for oocyte aspiration (6), second way for follicle flushing (4). Echogenic tip with atraumatic bevel (1). Oocyte […]
-
DOUBLECYTE-N
For atraumatic oocyte aspiration in IVF procedures. Double lumen, double-way needle, one way for oocyte aspiration (6), second way for follicle flushing (4). Echogenic tip with atraumatic bevel (1).Oocyte aspiration is performed […]
-
EASY-RAM
Semi-automatic disposable device with a “guillotine” cutting system, used for soft tissue biopsy. The cannula tip was designed to make the tissue penetration, the tissue cutting and the bioptic sampling […]
-
ERGO-RAM
Bone Marrow Aspiration Needle with Adjustable Needle Stop and ergonomic handle. The spinal triple sharpened tip allows a non traumatic, fast and easy penetration into the bone marrow cavity. The […]